TitleProduct

BFE Bacterial Filtration Efficiency Tester

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2020-12-15 10:42

  • Browse the number:

    264

Send an inquiries

Company Profile

Gangzhou Chenrui Intelligent Equipment Co., Ltd

By certification [File Integrity]

Contact:crzntest1186(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website:http://www.crzntecn.com/ http://crzntest1186.chinesenike.com/

Product Details


Bacterial Filtration Efficiency (BFE) Detector

It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate. The dual gas path simultaneous comparison sampling method is used to improve the accuracy of sampling, which is suitable for the performance testing of bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other relevant departments.


Specifications

Key Specification

Specification Range

Resolution

Accuracy

A Route Sampling Flow

28.3L/min

0.1L/min

Within ± 2.5%

B Route Sampling Flow

28.3L/min

0.1L/min

Within ±2.5%

Spray Flow

(8~10) L/min

0.1L/min

Within ±2.5%

Peristaltic Pump Flow

(0.006~3.0) mL/min

0.001ml/min

Within ±2.5%

Front Pressure of A Route Sampling Flowmeter

(-20~0) kPa

0.01kPa

Within ±2.5%

Front Pressure of B Route Sampling Flowmeter

(-20~0) kPa

0.01kPa

Within ±2.5%

Front Pressure of Spray Flowmeter

(0~300) kPa

0.1kPa

Within ±2.5%

Ambient Temperature

(-40~99) ℃

0.1℃

Within ±2.5%

Negative Pressure of the Aerosol Chamber

(-90~-120) Pa

0.1Pa

Within ±2.0%

Negative Pressure of the Cabinet

-50~-200pa

Data Storage Ability

>100000 sets

Vortex Mixer Test Tube Specification and Quantity

Φ16×150mm test tube, 8pcs

High Efficiency Particulate Air Filter Properties

Filter Efficiency ≥99.99% for particles> 0.3μm

Median diameter of aerosol generator mass

Average diameter: (3.0±0.3)μm; Geometric Standard Deviation≤1.5

Double Routes 6-lever Andersen Sampling apparatus

Level1>7μm; Level 2: (4.7~7)μm;

Level 3: (3.3~4.7)μm; Level 4: (2.1~3.3)μm;

Level 5: (1.1~2.1)μm; Level 6: (0.6~1.1)μm

Size of Aerosol Chamber

600×85×3mm (Length×Diameter×Thickness)

Total number of positive quality control sampler particles

(2200±500) cfu

Negative Chamber Flow Speed

≥5m3/min

Size of Negative Pressure Chamber Door (W×D)

1000×730mm

Size of Main Machine (W×D×H)

1180×650×1300mm

Size of Supporting Frame (W×D×H)

1180×650×600mm, Height within 10cm is adjustable

Noise of the Tester

<65dB(A)

Weight

150kg

Power Supply

AC220V±10%, 50Hz

Power Consumption

<1500W



Standards

YY0469-2004, YY/T 0969-2013, ASTMF2100, ASTMF2101, EN14683


Features

1. Negative pressure experiment system to ensure the safety of operators;

2. Negative pressure cabinet with built-in peristaltic pump and A and B two-way six-stage Andersen;

3. The flow rate of the peristaltic pump can be set;

4. Dedicated microbial aerosol generator can set the volume of bacterial liquid spray flow, and the atomization effect is good;

5. Embedded high-speed industrial microcomputer control;

6. 10.4-inch industrial-grade high-brightness color touch display;

7. USB interface, support U disk data transfer;

8. Built-in high-brightness lighting in the cabinet;

9. Built-in leakage protection switch to protect operator safety;

10. Insulation and flame retardant between inner and outer layers;

11. The front switch glass door is convenient for experimenters to observe and operate;

12. Detachable stand, the height of stand is adjustable;

13. Support and move dual-purpose casters.



Masks Bacterial Filtration Efficiency Tester is used to determine the bacterial filtration efficiency (BFE) of medical face masks, surgical face masks, to identify the protective performance from being exposed to bacterial airborne environments.

Masks Bacterial Filtration Efficiency Tester, BFE tester’s main performance indicators can meet both the YY0469-2011 in the appendix B bacterial filtration efficiency (BFE) test method B.1.1 test instrument requirements, and the ASTM ASTMF2100, ASTMF2101, European EN14683 standard requirements.

This mask bacterial filtration efficiency tester adopts the design of a double airway simultaneous comparison sampling method to improve the accuracy of sampling, applicable to metrological testing departments, scientific research institutions, mask manufacturers, and other relevant departments of the mask bacterial filtration efficiency performance testing.


Standards

· YY 0469 – 2011, YY/T 0969 – 2013

· ASTM F2100, ASTM F2101


Tester Specifications

Main parameter

Parameter range

A sampling flow

According to the specific requirement of TEST REPORT provided for each machine

B sampling flow

According to the specific requirement of TEST REPORT provided for each machine

Spray flow

According to the specific requirement of TEST REPORT provided for each machine

Peristatic pump flow

According to the specific requirement of TEST REPORT provided for each machine

Front pressure of flowmeter A

(-20 ~ 0) kPa

Front pressure of flowmeter B

(-20 ~ 0) kPa

Front pressure of spray flow

(0 ~ 300) kPa

Pressuring of aerosol

(-90 ~ -120) Pa

Working temperature

(0 ~ 50) ℃

Pressuring of cabinet

(-50 ~ -200) Pa

Data storage capacity

> 100000 set

Characteristics of high-efficiency air filter

The filtration efficiency of particles above 0.3 um ≥ 99.99%

Median mass diameter of aerosol generator

Mean particle diameter (3.0 ± 0.3) μm, geometric standard deviation ≤ 1.5

Two-way 6-stage Anderson sampler to capture particle size

Level Ⅰ>7μm, Level Ⅱ (4.7 ~ 7) μm, Level Ⅲ (3.3 ~ 4.7) μm, Level Ⅳ (2.1 ~ 3.3) μm, Level Ⅴ (1.1 ~ 2.1) μm, Level Ⅵ(0.6 ~ 1.1) μm

Aerosol chamber specifications

(Length 600 * Diameter 85 * Thickness 3) mm

Total particles of positive quality control sampler

(2200 ± 500) cfu

Ventilation flow of pressuring cabinet

≥ 5 m3/min

Size of pressuring cabinet door

1000 * 730 mm (L x W)

Host size

1180 * 650 * 1300 mm (L x W x H)

Bracket size

1180 * 650 * 600 mm (L x W x H), Height adjustable within 100 mm

Working power

AC 220 V ± 10%, 50 Hz

Noise

< 65 dB (A)

Weight

About 150 Kg

Power consumption

< 1500 W



Tester Features

· Pressuringtest system to ensure the safety of operators;

· Pressuringcabinet built-in peristaltic pump, A, B two-way six-stage Anderson;

· Peristaltic pump flow value can be set;

· Special microbial aerosol generator bacterial liquid spray flow valuecan be set;

· Good atomization;

· Embedded high-speed industrial microcomputer control;

· 4-inch industrial-grade high-brightness color touch display screen;

· USB interface, support U disk data transfer;

· Cabinet built-in high-brightness lighting lamp;

· Built-in leakage protection switch to protect the safety of operators;

· The inner layer of stainless steel in the cabinet is integrally processed and formed, and the outer layer is sprayed with cold-rolled plate;

· Heat preservation and flame retardant between inner and outer layers;

· Front switch type glass door, which is convenient for experimenters to observe and operate;

· Removable bracket with adjustable bracket height;

· Support and move dual-use casters.



http://www.crzntecn.com/